ST11 thermal protector

Main parts

1) Iron cover plate 2) stationary silver contact 3) spring disc

4) movable contact 5) housing 6) bimetal disc 7) Insulating paper


Construction

Stationary silver contact are riveted with iron cover plate.; The bimetal disc and spring disc are combined by steps on the movable contact. The current passes through the stationary silver contact to the movable contact, and then connects the housing through the spring disc to form a loop.


Function

When the circuit is normal, the movable contact is in close contact with the stationary silver contact under the pre-pressure of the spring disc. When the rated operating temperature is reached, the bimetal disc is deformed by heat, snaps into its inverted position and pushes the spring disc downwards. The contact is abruptly opened and the temperature rise of the device to be protected is disrupted.After the circuit is disconnected, the ambient temperature begins to fall.  When it reaches the defined reset temperature, the bimetal disc and the spring disc snaps back into its start position, the contacts will close again, and the circuit returns to the conduction state.

ST11 thermal protector

THE ST11 thermal protector SERIES

  • ST11_1
    ST11_2

    ST11

    Power class: 1,6 A to 7,5 A

    Type series: ST11 thermal protector

    normally closed
    resets automatically